Logga in
Åtkomst till upphandling
Kontakta oss
13 39 00 32 0
Sverige
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
Sverige
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
Kontakta oss
Logga in
Toggle navigation
Support
Mercell TendSign Sverige
Mercell Sverige Kundservice
Mercell Opic Sverige
Mercell CTM Svensk Kundtjänst (tidigare EU-Supply)
Upphandlingsbevakning
Mercell Opic Upphandlingskoll
Prova gratis i 7 dagar
Mercell Opic Upphandlingskoll
Prova gratis i 7 dagar
Tilläggstjänster
Kunskapsbank
Offentliga upphandlingar
Direktupphandling
Kunskapsbank
Offentliga upphandlingar
Direktupphandling
Upphandlingsbloggen
Prenumerera på vårt nyhetsbrev
Upphandlingsbloggen
Prenumerera på vårt nyhetsbrev
Sök upphandlingar
Upphandlingsverktyg
Mercell TendSign Upphandlingsverktyg
Utbildningar
Direktupphandlingar
För leverantörer
Mercell Leverantörsregister
Hemsidan
Upphandlingar
Size Exclusion Chromatography system
Information
Meddelandetyp
 
Upphandlingstyp
Förfarande
Öppet förfarande
Upphandlingsdatum
Förväntat avslutsdatum för upphandlingen
Publiceringsdatum
2022-11-17 10:00 (GMT+01:00)
Anbudsfrist
2022-11-30 11:00 (GMT+01:00)
Sista dag för att ställa frågor
Rekommenderad sista dag att visa intresse
Accepterar parallella anbud
Nej
Accepterar alternativa anbud
Nej
Inköpare
Upphandlande enhet
University of Helsinki
University of Helsinki
Avdelning
Kontakt
Katri Leino
Katri Leino
Adress
Yliopistonkatu 3
00100
Helsinki
Finland
Org.nr.
0313471-7
Hemsida
www.helsinki.fi
Anbudsfristen har passerat.
Kort beskrivning
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Minimum requirements for the system:
• HPLC-pump delivering a maximum pressure of at least 400 bar and having a flow rate range of 0,001-10,000 mL / min
• Autosampler; capable of injecting from at least 40 sample vials in one run
• HPLC or GPC Solvent degasser
• Column oven; capable to accommodate at least 3 columns, each column having a length of 300 mm
• Triple detection comprising of low- and right angle laser light scattering detector (RALS and LALS), viscosity detector and IR-detector
• UV-detector capable in operating in dual mode and having a wavelength range of at least 190-600 nm
• Fluorescence detector; having a wavelength range of at least 200-890 nm for exitation and 210-900 for emission.
• All parts of the system need to be compatible with at least the following solvents: H2O, Phosphate buffers, Dimethylformamide, Tetrahydrofuran, Chloroform, Acetonitrile and Dichloromethane
• The system must have warranty at least for 12 months.
• The policy for software upgrades and their pricing must be included.
• The instrument should be new one. No prototypes allowed.
• A windows 10 computer and a monitor to operate the instrument with all the necessary programs installed.
• The instrument is CE-marked.
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Minimum requirements for the system:
• HPLC-pump delivering a maximum pressure of at least 400 bar and having a flow rate range of 0,001-10,000 mL / min
• Autosampler; capable of injecting from at least 40 sample vials in one run
• HPLC or GPC Solvent degasser
• Column oven; capable to accommodate at least 3 columns, each column having a length of 300 mm
• Triple detection comprising of low- and right angle laser light scattering detector (RALS and LALS), viscosity detector and RI-detector
• UV-detector capable in operating in dual mode and having a wavelength range of at least 190-600 nm
• Fluorescence detector; having a wavelength range of at least 200-890 nm for exitation and 210-900 for emission.
• All parts of the system need to be compatible with at least the following solvents: H2O, Phosphate buffers, Dimethylformamide, Tetrahydrofuran, Chloroform, Acetonitrile and Dichloromethane
• The system must have warranty at least for 12 months.
• The policy for software upgrades and their pricing must be included.
• The instrument should be new one. No prototypes allowed.
• A windows 10 computer and a monitor to operate the instrument with all the necessary programs installed.
• The instrument is CE-marked.
Dokument (klicka på filnamnet för att ladda ner)
Namn
Filstorlek
Size Exclusion Chromatography system.pdf
485 KB
Size Exclusion Chromatography system.zip
2,52 MB
Mercell Commerce
Del av Mercellgruppen, en av Europas ledande leverantörer av elektroniska upphandlings- och anbudssystem på den professionella marknaden.
Produkter
Upphandlingsbevakning
Upphandlingsverktyg
Marknadsbevakning
Kommande upphandlingar
Mercell
Om oss
Investor
Etiska riktlinjer
Samarbetspartner
Karriär
Nyheter
Kontakta oss
Klicka här för att gå till vår support
+46 13 39 00 32 0
Mercell Commerce
|
Klara Södra kyrkogata 1
,
11152
Stockholm
,
Sverige
Integritetspolicy
|
Cookies
|
Användarvillkor
|
Kontakta oss
|
Logga in