Sign in
Tender access
Contact us
21 01 88 00
World
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
World
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
Contact us
Sign in
Toggle navigation
Support
Mercell Customer Service
Mercell CTM Customer Service (former EU-Supply)
Mercell Udbudsvagten Customer Service
Mercell Ethics Customer Service
Mercell TrueLink Customer Service
Mercell Comcare Customer Service
Mercell Tricom Customer Service
Mercell Opic Customer Service
Mercell TendSign Customer Service
Mercell Negometrix Customer Service
Mercell Ajour Innkjøp Customer Service
Investors
Overview
About Mercell
News
Reports & Presentations
Financial Calendar
General meeting
Corporate Governance
Governance overview
Executive Management
Board of Directors
Committee Composition
Corporate Governance
Governance overview
Executive Management
Board of Directors
Committee Composition
Share Information
Share Data
Dividend Policy
Share ownership
Primary Insiders
Analyst Coverage
Registrar & Auditor
Share Information
Share Data
Dividend Policy
Share ownership
Primary Insiders
Analyst Coverage
Registrar & Auditor
Debt Information
Contact
Investor Email Alerts
Investor Contacts
Contact
Investor Email Alerts
Investor Contacts
About us
Contact us
Become a Partner
Career
Departments
Ethical guidelines
Tender terminology
Procurement solutions
Tender Alert
Plans and pricing
ESPD
Website
Tenders
Size Exclusion Chromatography system
Information
Notice type
 
Tender type
Procedure
Open procedure
Estimated tendering starting date
Estimated tendering closing date
Publication date
11/17/2022 10:00 AM (GMT+01:00)
Closing date
11/30/2022 11:00 AM (GMT+01:00)
Questions closing date
Recommended document due date
Accepts parallel bids
No
Accepts variant bids
No
Buyer
Name
University of Helsinki
University of Helsinki
Department
Contact
Katri Leino
Katri Leino
Address
Yliopistonkatu 3
00100
Helsinki
Finland
Org. number
0313471-7
Website
www.helsinki.fi
Closing date has passed.
Short description
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Minimum requirements for the system:
• HPLC-pump delivering a maximum pressure of at least 400 bar and having a flow rate range of 0,001-10,000 mL / min
• Autosampler; capable of injecting from at least 40 sample vials in one run
• HPLC or GPC Solvent degasser
• Column oven; capable to accommodate at least 3 columns, each column having a length of 300 mm
• Triple detection comprising of low- and right angle laser light scattering detector (RALS and LALS), viscosity detector and IR-detector
• UV-detector capable in operating in dual mode and having a wavelength range of at least 190-600 nm
• Fluorescence detector; having a wavelength range of at least 200-890 nm for exitation and 210-900 for emission.
• All parts of the system need to be compatible with at least the following solvents: H2O, Phosphate buffers, Dimethylformamide, Tetrahydrofuran, Chloroform, Acetonitrile and Dichloromethane
• The system must have warranty at least for 12 months.
• The policy for software upgrades and their pricing must be included.
• The instrument should be new one. No prototypes allowed.
• A windows 10 computer and a monitor to operate the instrument with all the necessary programs installed.
• The instrument is CE-marked.
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Size Exclusion Chromatography (SEC) system will be acquired for Department of Chemistry, University of Helsinki.
Minimum requirements for the system:
• HPLC-pump delivering a maximum pressure of at least 400 bar and having a flow rate range of 0,001-10,000 mL / min
• Autosampler; capable of injecting from at least 40 sample vials in one run
• HPLC or GPC Solvent degasser
• Column oven; capable to accommodate at least 3 columns, each column having a length of 300 mm
• Triple detection comprising of low- and right angle laser light scattering detector (RALS and LALS), viscosity detector and RI-detector
• UV-detector capable in operating in dual mode and having a wavelength range of at least 190-600 nm
• Fluorescence detector; having a wavelength range of at least 200-890 nm for exitation and 210-900 for emission.
• All parts of the system need to be compatible with at least the following solvents: H2O, Phosphate buffers, Dimethylformamide, Tetrahydrofuran, Chloroform, Acetonitrile and Dichloromethane
• The system must have warranty at least for 12 months.
• The policy for software upgrades and their pricing must be included.
• The instrument should be new one. No prototypes allowed.
• A windows 10 computer and a monitor to operate the instrument with all the necessary programs installed.
• The instrument is CE-marked.
Files (click "Show interest" to get access)
Name
Size
Size Exclusion Chromatography system.pdf
485 KB
Size Exclusion Chromatography system.zip
2.52 MB
Mercell Holding AS
Part of the Mercell Group, one of Europe’s leading providers of e tender systems and information between buyers and suppliers in the professional market.
Our products
Tender offer
ESPD
Tender consulting
E-tendering system
Blog
About us
The company
Investor
Departments
Mercell's Code of Conduct
Offer for EU-Supply Plc
Tender terminology
Career
Contact us
Write to us
+47 21 01 88 00
Mercell Holding AS
|
Askekroken 11
,
0277
OSLO
,
Norway
Privacy policy
|
Cookie info
|
Terms & conditions
|
Contact us
|
Sign in