75144 RH KIT Inner Medical Research Multi-array Instrument

Information

Award of a contract without prior publication of a contract notice in the Official Journal of the European Union
5/29/2018 9:36 AM (GMT+02:00)

Buyer

Oslo universitetssykehus HF Oslo universitetssykehus HF
Trine Kjellsen
Postboks 4950 Nydalen
0424 Oslo
Norway
993 467 049

Assignment text

Oslo universitetssykehus HF 993 467 049 Postboks 4950 Nydalen Oslo 0424 Trine Kjellsen +47 91667242 trikje@ous-hf.no www.ous-hf.no 75144 RH KIT Inner Medical Research Multi-array Instrument 75144 Oslo University Hospital, KIT Institute for internal medical research, shall procure a multi-array instrument with electrochemical luminescence detection technology for research. 2080000.00 Oslo University Hospital. Oslo University Hospital, KIT Institute for internal medical research, shall procure a multi-array instrument with electrochemical luminescence detection technology for research. The procurement will be carried out via ex ante transparency notice. The multi-array instrument must have: Kit and technology: — Electrochemical luminescence (ECL) detection technology. — Broad dynamic area — 3-4 logs. — High sensitivity — Recommended in the area of 1pg/ml (LLOD). — Low sample volume — 25ul in both individual and multiplex formats (samples). — High matrix tolerance — allows exact quantifying of regular complex samples/formats (serum, plasma, tissue lysates, CSF, BAL, sputum, etc.). — Internally validated kit for long-term stability. Instrument: — Only an instrument that allows the detection of plate-based Electrochemical luminescence (ECL). — Non-fluid system — no samples get into the instrument, no cleaning and calibration required. — Short reading time — maximum 100 seconds for a full 96 well multiplex plate. — Free downloadable software for data analysis. Plate-based Electrochemical luminescence (ECL) is the proprietor for Mesoscale (MSD) and it is the only company that produces and sells instruments and reagents for this technology. It is, however, an open platform, which enables customers to develop their own analyses on the unprepared well plates. This is based on Meso Scale discovery being the only supplier that, due to technical reasons, can deliver in accordance with the requirements. The intention notice is pursuant to the public procurement regulations § 21-5. The terms in FOA § 13-4 (2) and 13-1 (5) are deemed to be fulfilled as well as the value of the full service contract for the instrument´s lifetime and consumables. Service contracts. Oslo University Hospital, KIT Institute for internal medical research, shall procure a multi-array instrument with electrochemical luminescence detection technology for research. The procurement will be carried out via ex ante transparency notice. The multi-array instrument must have: Kit and technology: — Electrochemical luminescence (ECL) detection technology. — Broad dynamic area — 3-4 logs. — High sensitivity — Recommended in the area of 1pg/ml (LLOD). — Low sample volume — 25ul in both individual and multiplex formats (samples). — High matrix tolerance — allows exact quantifying of regular complex samples/formats (serum, plasma, tissue lysates, CSF, BAL, sputum, etc.). — Internally validated kit for long-term stability. Instrument: — Only an instrument that allows the detection of plate-based Electrochemical Luminescence (ECL). — Non-fluid system — no samples get into the instrument, no cleaning and calibration required. — Short reading time — maximum 100 seconds for a full 96 well multiplex plate. — Free downloadable software for data analysis. Plate-based Electrochemical luminescence (ECL) is the proprietor for Mesoscale (MSD) and it is the only company that produces and sells instruments and reagents for this technology. It is, however, an open platform, which enables customers to develop their own analyses on the unprepared well plates. This is based on Meso Scale discovery being the only supplier that, due to technical reasons, can deliver in accordance with the requirements. The intention notice is pursuant to the public procurement regulations § 21-5. The terms in FOA § 13-4 (2) and 13-1 (5) are deemed to be fulfilled as well as the value of the full service contract for the instrument´s lifetime and consumables. 7144 RH KIT Inner medical research Multi-array instrument 2018-05-23 Meso Scale Discovery 1601 Research Boulevard Rockville MD 20850 +001 2403142600 customerservice@meso-scale.com 2080000.00 Oslo Universitetssykehus HF Sognvannsveien 20 Oslo 0372 +47 23071580 mtu-anbud@ous-hf.no www.ous-hf.no Appeals deadline 4.6.18. 2018-05-25

See tender at TED: http://ted.europa.eu/udl?uri=TED:NOTICE:229924-2018:TEXT:EN:HTML

Mercell Holding AS

Part of the Mercell Group, one of Europe’s leading providers of e tender systems and information between buyers and suppliers in the professional market.

Contact us

Write to us

+47 21 01 88 00