Sign in
Tender access
Contact us
21 01 88 00
World
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
World
Danmark
Deutschland
Eesti
Latvija
Lietuva
Norge
Polska
Russia
Suomi
Sverige
World
UK & Ireland
USA
Nederland
България
Contact us
Sign in
Toggle navigation
Support
Mercell Customer Service
Mercell CTM Customer Service (former EU-Supply)
Mercell Udbudsvagten Customer Service
Mercell Ethics Customer Service
Mercell TrueLink Customer Service
Mercell Comcare Customer Service
Mercell Tricom Customer Service
Mercell Opic Customer Service
Mercell TendSign Customer Service
Mercell Negometrix Customer Service
Mercell Ajour Innkjøp Customer Service
Investors
Overview
About Mercell
News
Reports & Presentations
Financial Calendar
General meeting
Corporate Governance
Governance overview
Executive Management
Board of Directors
Committee Composition
Corporate Governance
Governance overview
Executive Management
Board of Directors
Committee Composition
Share Information
Share Data
Dividend Policy
Share ownership
Primary Insiders
Analyst Coverage
Registrar & Auditor
Share Information
Share Data
Dividend Policy
Share ownership
Primary Insiders
Analyst Coverage
Registrar & Auditor
Debt Information
Contact
Investor Email Alerts
Investor Contacts
Contact
Investor Email Alerts
Investor Contacts
About us
Contact us
Become a Partner
Career
Departments
Ethical guidelines
Tender terminology
Procurement solutions
Tender Alert
Plans and pricing
ESPD
Website
Tenders
Energy dispersive x-ray microanalysis spectrometer (EDS) and a sputter coating device
Information
Notice type
 
Tender type
Procedure
Open procedure
Estimated tendering starting date
Estimated tendering closing date
Publication date
6/16/2023 9:35 AM (GMT+02:00)
Closing date
6/30/2023 11:00 AM (GMT+02:00)
Questions closing date
Recommended document due date
Accepts parallel bids
No
Accepts variant bids
No
Buyer
Name
Kaakkois-Suomen Ammattikorkeakoulu Oy
Kaakkois-Suomen Ammattikorkeakoulu Oy
Department
Contact
Nuutti Teräsalmi
Nuutti Teräsalmi
Address
Patteristonkatu 3 D
50100
Mikkeli
Finland
Org. number
2472908-2
Website
www.xamk.fi
Closing date has passed.
Short description
South-Eastern Finland University of Applied Sciences (Xamk) is purchasing a energy dispersive x-ray microanalysis spectrometer (EDS) and a sputter coating device according to this tender documentation. Equipment will be located to Mikpolis RDI-unit in Mikkeli.
Pricing must include shipping costs to Mikkeli Finland (Patteristonkatu 3, 50100 Mikkeli, Finland).
Installation and user training must be included.
The EDS system should be installed on a Hitachi S-4800 cold field emission scanning electron microscope (SEM) already installed in the lab and to replace an existing EDS system.
Beam control interface and EDS communications software already exist in the SEM.
As the SEM is optimized for high magnification studies it uses a magnetic immersion lens and its maximum beam current is 20 nA at 30kV the detector should be capable of x-ray collection at high solid angle and operation at short working distance.
The system is used both with the magnetic immersion lens switched on (high mag observation) and off (low mag observation). This needs to be considered when selecting an appropriate collimator and BSE trap.
Sample exchange is done through a load lock to keep the specimen chamber always under vacuum which would allow for a windowless EDS detector.
As the laboratory often look at glass and materials containing boron (B) a windowless EDS detector option is of interest but not mandatory.
To match the high resolution performance of the SEM Xamk is also purchasing a high resolution sputter coater at the same time.
The coater should be capable at achieving high vacuum conditions (<1x10-5mb) for smallest possible grain size and flexibility when selecting sputter target materials.
A sample chamber of at least 150 mm diameter to allow large samples or multiple smaller samples is preferred.
The sample stage should allow both rotation and tilt to improve performance on rough sample surfaces.
Coating thickness should be monitored during the coating process and it should be possible to set automatic stop conditions based on achieved coating thickness.
Sputter targets should preferrably be of small diameter to minimize the material waste and targets for Ni, Cr, and Au/Pd should be included with the system.
Files (click "Show interest" to get access)
Name
Size
Energy dispersive x-ray microanalysis spectrometer (EDS) and a sputter coating device.pdf
472 KB
Mercell Holding AS
Part of the Mercell Group, one of Europe’s leading providers of e tender systems and information between buyers and suppliers in the professional market.
Our products
Tender offer
ESPD
Tender consulting
E-tendering system
Blog
About us
The company
Investor
Departments
Mercell's Code of Conduct
Offer for EU-Supply Plc
Tender terminology
Career
Contact us
Write to us
+47 21 01 88 00
Mercell Holding AS
|
Askekroken 11
,
0277
OSLO
,
Norway
Privacy policy
|
Cookie info
|
Terms & conditions
|
Contact us
|
Sign in