Supply and Installation of a new SCADA/EMS system for the National Dispatch Centre, Back-up Dispatch Centre and Market Management System.

Hange

Avatud menetlus
08.11.2013 5:30 (GMT+02:00)

Hankija

AD MEPSO AD MEPSO
AD MEPSO AD MEPSO
Anton Petrovski
Orce Nikolov bb
1000 Skopje

Eesmärk

Supply and Installation of a new SCADA/EMS system for the National Dispatch Centre, Back-up Dispatch Centre and Market Management System, to support the following: to support the following:

Supply and Installation of a SCADA Control System for the National Dispatch Centre (NDC);

Supply and Installation of a SCADA Control System for the Back-up Dispatch Centre;

Supply and Installation of the Energy Management System (EMS) for NDC and Back-up Dispatch Centre consisting of the following functions:

— Network Modelling,

— State Estimator,

— Bus Load Forecast,

— Contingency Analysis,

— Operator Load Flow,

— Short Circuit Analysis,

— Automatic Generation Control which has to be compliant with ENTSO-E requirements,

— Operator (Dispatcher) Training Simulator,

— Outage Scheduler,

Supply and Installation of a Market Management System (MMS) for NDC and Back-up Dispatch Centre including:

— Market Participants Management,

— Contracts Management,

— Scheduling System,

— The System for Administration of the Imbalance Settlement,

— Ancillary Services Management,

— Transmission Capacity Management,

Supply and Installation of a Private Automatic Branch Exchange with integrated voice over IP functionalities (IP- PBX) and a Voice Recording System (VRS).

— The Tenderer shall offer a well proved SCADA/EMS/MMS System and IP/PBX/VRC system which includes all of the technical characteristics required by the Employer as a standard.

SCADA and EMS (AGC) software shall be developed and maintained by the Tenderer or his subsidiaries.

Supplied SCADA/EMS Systems should integrate the existing Telecontrol System (RTUs and Substation Automation Control Systems (SACSs)).

— The new systems have to provide the standard communication protocols IEC60870-5-101,IEC60870-5-104 and ICCP (TASE2).

The new Systems have to provide central data base management with update to the NDC and Back-up DC (sites) and parameterize data value update between the sites.

During the transition from the existing system to the new system, the parallel operation with the existing system is required to avoid any loss of data.

Section V: Award of contract

V.1.1) Date of contract award decision:

29.3.2013

V.1.2) Information about offers

Number of offers received: 3

V.1.3) Name and address of economic operator in favour of whom the contract award decision has been taken

Telephone: E-mail: Fax: Internet address: Siemens AG Österreich IC SG E A SOL, Ruthnergasse 3, 1210 Vienna, AUSTRIA +43 5170745547, lubomir.mintchev@siemens.com +43 5170756256, http://www.siemens.com

Mercell Estonia OÜ

Mercelli gruppi kuuluv Euroopa juhtiv e-hanke keskkond vahendab infot ostjate ja tarnijate vahel.

Kontakt

Mercell Eesti kasutajatugi

+372 683 6785
Mercell Estonia OÜ | Põhja puiestee 21C, 10143 Tallinn, Eesti